Calibrated equipment
Measuring receivers (EMI receivers, spectrum analyzers)
Calibration method - according to EN 55016-1-1 standard.
If you do not need the full calibration scope please provide:
- Detectors (QP, Peak, Average/CISPR Average, RMS),
- Number of measurement inputs,
- Frequency scope for each of the measurement inputs.
Optionally: statement of conformity of the results with the requirements of the EN 55016-1-1 standard.
Pulse generators
Calibration method – according to EN 55016-1-1 standard.
Optionally: statement of conformity of the results with the requirements of the EN 55016-1-1 standard .
Discontinuous disturbance analyzers
Calibration method - according to EN 55016-1-1 standard.
Optionally: statement of conformity of the results with the requirements of the EN 55016-1-1 standard.
Artificial networks / ISNs
Calibration method - according to EN 55016-1-2 standard.
Calibration scope - in accordance with the technical documentation of the device and the applicable standard.
If the network operates in different modes (e.g. limiter/filter/internal terminator), please specify the settings in which the calibration is to be performed.
Optionally: statement of conformity of the results with the requirements of EN 55016-1-2, ISO 7637-2 and EN 55025 standards.
Absorption clamps
Calibration method - according to EN 55016-1-3 standard.
Please specify in the inquiry, whether the absorption clamps are to be calibrated with an attenuator and a cable.
Antennas
Calibration method - according to EN 55016-1-6, SAE ARP 958, or ANSI standard.
Please provide the following:
- Calibration standard,
- Measurement distance,
- Frequency scope and measurement step,
- Polarizations (horizontal, vertical),
- Modes (if the antenna has any).
Voltage probes
Calibration method - according to EN 55016-1-2 standard.
Optionally: statement of conformity of the results with the manufacturer's technical documentation.
Current probes/ Pearson probes
Calibration method - according to EN 55016-1-2 standard.
Calibration scope for the current probe – in accordance with its technical documentation.
Power meters and probes
Calibration method – in compliance with the Laboratory’s in-house, accredited method.
Basic calibration is performed as a function of frequency at: 10 dBm, 0 dBm, -15 dBm. Please let us know if testing at other levels is required.
CDNs
Calibration method - according to EN 55016-1-2 standard.
Optionally: statement of conformity of the results with the requirements of the EN 61000-4-6 standard.
ESD generators
Calibration method - according to EN 61000-4-2 or ISO 10605 standard.
Optionally: statement of conformity of the results with the requirements of EN 61000-4-2 or ISO 10605 standards.
EFT/B generators with additional devices
Calibration method - according to EN 61000-4-4, ISO 7637-2 or ISO 7637-3 standard.
Optionally: statement of conformity of the results with the requirements of EN 61000-4-4, ISO 7637-2 or ISO 7637-3 standards.
SURGE generators with additional devices
Calibration method - according to EN 61000-4-5 standard.
Optionally: statement of conformity of the results with the requirements of the EN 61000-4-5 standard.
Passive elements
Calibration method – in compliance with the Laboratory’s in-house, accredited calibration method focusing on attenuation and standing wave ratio.
Ring wave generators
Calibration method - according to EN 61000-4-12 standard.
Optionally: statement of conformity of the results with the requirements of the EN 61000-4-12 standard.
Damped oscillatory wave generators
Calibration method - according to EN 61000-4-18 standard.
Optionally: statement of conformity of the results with the requirements of the EN 61000-4-18 standard.
Generators for voltage dips, short interruptions and voltage variations
Calibration method - according to PN- EN 61000-4-11 standard.
Optionally: statement of conformity of the results with the requirements of the PN- EN 61000-4-11 standard.
Calibration lead time:
Approximate calibration lead time per one device. For higher device quantities, the lead time is determined on a case-by-case basis.
Standard – 5-10 business days.
Express – From 3 business days. Please inquire for details.
Without any prior arrangements concerning the completion date – up to 15 business days.
The lead times specified above do not apply to antennas requiring measurements performed at an Open Area Test Site (OATS).